INSTALLATION AND OPERATOR’S MANUAL
SL375 THRU SL7175
CAST IRON BOILERS
Keep these instructions with the boiler at all times for
future reference
B
OYERTOWN FURNACE CO.
PO Box 100
B
OYERTOWN, PA 19512
1-610-369-1450
www.boyertownfurnace.com
9-1-13
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - SL375 THRU SL7175

INSTALLATION AND OPERATOR’S MANUAL SL375 THRU SL7175 CAST IRON BOILERS Keep these instructions with the boiler at all times for future r

Seite 2

10the vent pipe connector shall not exceed 10 feet. The chimney connector shall be installed so as to minimize the number of elbows and to avoid sha

Seite 3 - Table of Contents

11Direct Venting Oil Fired Boilers Failure to follow all instructions can result in flue gas spillage and carbon monoxide emissi

Seite 4 - Ratings and Data

123. COMBINATION AIR INTAKE/VENT SYSTEM The vent system consists of 10 or 15 foot lengths of double wall insulated flexible stainless vent piping an

Seite 5 - Warning…

13DIRECT VENT OIL BURNERS Riello Burners All Riello direct vent burners are shipped with the nozzle for the SLD375 installed. A separate nozzle is

Seite 6 - Boiler Assembly

14 On a two- pipe system you will need to supply a second approved flexible oil line in order to be able to swing the burner door open without discon

Seite 9

17Swing Door Opening the Door 1. Turn off power to boiler. 2. Allow boiler to cool down. 3. Unplug the burner power cable at factory-supplied bur

Seite 10

18Start-Up Warning…Use only … No. 2 fuel oils. Note: Do not attempt to start the burner if excess oil has accumulated. Note: Do not use gasol

Seite 11 -

19Preliminary Oil Burner Settings Boiler Burner Nozzle Air Setting Turbulator/ Head Pump Press CO2 Draft Overfire Smoke SL375 Riello F3 .55x60oA 2.

Seite 12

2Danger WarningCaution Notice WarningBe Aware of Hazard Definitions Denotes presence of a hazard which, if ignored, will result in severe personal in

Seite 13 - Oil Tank and Piping

20Do not use the boiler if any part has been under water. Call a qualified service technician to inspect the boiler and replace any part of the cont

Seite 14 - Electrical Wiring

21 Item Qty. Description SL375 SL4100 SL5215 SL6150 SL6175 1 1 Riello F-3 541151 N/A N/A N/A N/A 1 1 Riello F-5 Oil Burner N/

Seite 15

22Solaia Residential Cast Iron Boiler Warranty First Year Limited Warranty for Solaia Residential Cast Iron Water Boilers Boyertown Furnace warrants

Seite 16

23Installation and Service Check List Boiler Model: _______________________ Serial No.: ____________________ Installa

Seite 17 - Operation

24 -----------------Cut and Return This Form or register online at www.boyertownfurnace.com-----------------

Seite 18

3Table of Contents Ratings and Data………………………………………………………………………4 Clearances……………………………………………………………………...5 Ventilation and Combustion A

Seite 19 - Maintenance

4Ratings and Data Boiler Model No. SL375 SLD375 SL4100 SLD4100 SL5125 SLD5125 SL6150 SL7175 Firing Rate - #2 Fuel 0.75 0.75 1.00 1.00 1.2

Seite 20 - Vent System

5Installation Clearances Boilers in rooms shall be installed with the clearances from combustible materials not less than indic

Seite 21

6hundred (100) square inches. These openings must freely communicate with the interior areas having adequate infiltration from the outside. When t

Seite 22

7 Boiler Trim Piping 1. Knocked down- Install the ¾” temperature control immersion well in upper right side tapping of the rear boiler section.

Seite 23

8Pipes that are connected to boiler fittings must be supported and placed so that they do not create stresses on the boiler fittings themselves. BY

Seite 24

9 Prior to installation of the boiler, the chimney or venting system shall be examined by the installer and determined to be in good condition. All j